- Lapping is not allowed for the bars having diameters more than 36mm.
- Chair spacing maximum is 1.00mm or 1 no per 1m2.
- For dowels rod minimum of 12mm diameter should be used.
- Chair minimum of 12mm diameter bars to be used.
- Longitudinal reinforcement not less than 0.8% and more than 6% of cross section.
- Minimum bars for square column is 4 No’s and 6 No’s for circular column.
- Main bars in the slabs shall not be less than 8mm or 10mm and the distributors not less than 8mm and not more than 1/8 of slab thickness.
- Minimum thickness of slab is 125mm.
- Dimension tolerance for cubes +_ 2mm.
- Free fall of concrete is allowed maximum to 1.50m.
- Lap slices not be used for bar larger than 36mm.
- Water absorption of bricks should not be more than 15%.
- PH value of the water should not be less than 6.
- Compressive strength of bricks is 3.5N/mm2 .
- In steel reinforcement binding wire required is 8 kg per MT.
- In soil filling as per IS code, 3 sample should be taken for core cutting test for every 100m2.
- Density of concrete block is 1920kg/m3.
- Density of reinforced concrete is 2310 – 2700kg/m3.