Site engineer tips and needs to know below basics

  • Lapping is not allowed for the bars having diameters more than 36mm.
  • Chair spacing maximum is 1.00mm or 1 no per 1m2.
  • For dowels rod minimum of 12mm diameter should be used.
  • Chair minimum of 12mm diameter bars to be used.
  • Longitudinal reinforcement not less than 0.8% and more than 6% of cross section.
  • Minimum bars for square column is 4 No’s and 6 No’s for circular column.
  • Main bars in the slabs shall not be less than 8mm or 10mm and the distributors not less than 8mm and not more than 1/8 of slab thickness.
  • Minimum thickness of slab is 125mm.
  • Dimension tolerance for cubes +_ 2mm.
  • Free fall of concrete is allowed maximum to 1.50m.
  • Lap slices not be used for bar larger than 36mm.
  • Water absorption of bricks should not be more than 15%.
  • PH value of the water should not be less than 6.
  • Compressive strength of bricks is 3.5N/mm2 .
  • In steel reinforcement binding wire required is 8 kg per MT.
  • In soil filling as per IS code, 3 sample should be taken for core cutting test for every 100m2.
  • Density of concrete block is 1920kg/m3.
  • Density of reinforced concrete is 2310 – 2700kg/m3.